Bihar SBTE Diploma Chemical 5th SEM Dec 2019 Paper on C.I.P.C

Bihar SBTE Diploma Chemical 5th SEM Dec 2019 Paper on C.I.P.C

Sr. No. Questions with options
1 Temperature is an ____ quantity

(a)  Extensive

(b) Intensive

(c)  Both (a) & (b)

(d) Neither of the both

2 Element in elastic type pressure gauge is of the type of

(a)  Bourdon tube

(b) Capsull

(c)  Bellows

(d) All of the above

3 Which of the following characteristics of an instrument is desirable

(a)  Accuracy

(b) Reproducibility

(c)  Sensitivity

(d) All of the above

4 The time constant of mercury in glass thermometer is

(a)  mc/hA

(b) hA/mc

(c)  mchA

(d) 1/mchA

5 Platinum resistance thermometer can be used up to

(a)  Silver point

(b) Antimony point

(c)  Gold point

(d) Zinc point

6 Which one of the following is a first order instrument

(a)  Bimetallic thermometer

(b) Vapor pressure thermometer

(c)  Mercury in glass thermometer

(d) Any one of the above

7 Mcleoid gauge is

(a)  U-tube filled by mercury

(b) U-tube filled low vapor pressure oil

(c)  Liquid manometer along with pressure amplifier

(d) Any one of the above

8 simple pitot tube measures

(a)  Average velocity

(b) Maximum velocity

(c)  Point velocity

(d) Static pressure

9 Starting temperature of optical radiation pyrometer is

(a)  800 degree Celsius

(b) 400 degree Celsius

(c)  1200 degree Celsius

(d) 1500 degree Celsius

10 Pressure of 0.01 Psi (absolute) can be measured by –

(a)  Ionization gauge

(b) Pirani gauge

(c)  Macloid gauge

(d) None of the se

11 Ordinary mercury thermometer comes under order –

(a)  First

(b) Second

(c)  Third

(d) None of these

12 Range of hydrogen in constant volume thermometer is

(a)  – 10 to 50 degree Celsius

(b) 0 to 100 degree Celsius

(c)  100 to 200 degree Celsius

(d) 100 to 500 degree Celsius

13 pH of an acid is

(a)  Less than 7

(b) Greater than 7

(c)  Equal to 7

(d) None of these

14 Thermocouple is suitable for measuring

(a)  Liquid temperature only

(b) Very high temperature only

(c)  Very low temperature only

(d) Both (b) & (c)

15 Which of the following is variable are flow meter?

(a)  Rotameter

(b) Orificemeter

(c)  Venturimeter

(d) Pitot tube

16 Thermistors are included in the class of solids called ____

(a)  Conductor

(b) Semi conductor

(c)  Insulator

(d) None of these

17 The level of liquid under pressure can be determined by using

(a)  Bubbler system

(b) Differential pressure manometer

(c)  Diaphragm box system

(d) Air trap system

18 ______ controller has the maximum stabilizing time

(a)  P

(b) PD

(c)  PI

(d) PID

Data Collected By – Rashmi
Published On – 15th June 2022

Posted

in

by

Tags:

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *